Abstract
A combustion products analyzer (CPA) was built for use on the Shuttle in response to several thermodegradation incidents during early flights. When the Toxicology Laboratory at Johnson Space Center (JSC) began to assess the air quality monitoring needs for the International Space Station (ISS), the CPA was the starting point for the design of a thermodegradation event monitor. The final product was significantly different from the CPA and was named the “compound specific analyzer-combustion products” (CSA-CP). One major change from the CPA was the replacement of the hydrogen fluoride sensor with an oxygen sensor. The focus of this paper will be the CSA-CP oxygen sensor’s ground testing, performance on ISS, and reduced pressure testing in response to a need on ISS.
Authors
Topic
Citation
Limero, T., Beck, S., and James, J., "Development and Performance of the Oxygen Sensor in the CSA-CP Aboard the International Space Station," SAE Technical Paper 2004-01-2337, 2004, https://doi.org/10.4271/2004-01-2337.Also In
References
- Coleman, M. STS-6 Toxicology Mission Report NASA-Johnson Space Center 1982
- Coleman, M. STS-28 Toxicology Mission Report NASA-Johnson Space Center 1989
- James, J.T. “Toxicological Basis for Establishing Spacecraft Air Monitoring Requirements” SAE Technical Paper Series 981738 , 28 th International Conference on Environmental Systems, Warrendale, PA 1998
- Limero, T. Beck, S. James, J.T. “The Portable Monitor for Measuring Combustion Products Aboard the International Space Station” SAE Technical Paper Series 2002-01-2298 , 32 nd International Conference on Environmental Systems, San Antonio, Texas July 2002
- ibid.
- Delgado, R. Davis, D. “Test Report: Evaluation of Compound Specific Analyzer-Combustion Products (CSA-CP),” May 14 1998 Lyndon B. Johnson Space Center, White Sands Test Facility P. O. Box 20, Las Cruces, NM
- Delgado, R. Davis, D. “Test Report: Evaluation of Compound Specific Analyzer-Combustion Products (CSA-CP),” January 26 1999 Lyndon B. Johnson Space Center, White Sands Test Facility P. O. Box 20, Las Cruces, NM
- City Technologies: Oxygen Sensors website: http://www.citytech.com
- Henderson, Robert E. Portable Gas Detectors Used in Confined Space and Other Industrial Atmospheric Monitoring Programs Website: http://pksafety.com/pk_rae_confspace.pdf