This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Evaluation of 3D Kinematic Model of the Spine for Ergonomic Analysis
Technical Paper
2004-01-2198
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Optoelectronic devices for movement analysis allow for the functional evaluation of motor abilities of the human body both healthy and pathological. Our group has developed a specific protocol for the lumbar spine obtaining promising results also in clinical applications. However the main critical issue in these methods is the skin motion artifacts that could affect measures: In fact preliminary experiments show two sources of error in the biomechanical model identification needed for the angle computation during flexion movements: a) markers related to the spinous processes shift their positions with respect to the correspondent vertebra and b) lumbar back muscles influence the position of markers correspondent to the transverse process of the vertebra. This study aims at preliminary evaluating these errors through an innovative protocol based on a joint MRI and optoelectronic analysis.
Authors
- G. L. Ciavarro - Dipartimento di Bioingegneria - Politecnico di Milano, Milan, Italy
- A. Tramonte - Dipartimento di Bioingegneria - Politecnico di Milano, Milan, Italy
- M. Fusca - Dipartimento di Bioingegneria - Politecnico di Milano, Milan, Italy
- G. C. Santambrogio - Dipartimento di Bioingegneria - Politecnico di Milano, Milan, Italy
- G. Andreoni - Dipartimento di Bioingegneria - Politecnico di Milano, Milan, Italy
Citation
Ciavarro, G., Tramonte, A., Fusca, M., Santambrogio, G. et al., "Evaluation of 3D Kinematic Model of the Spine for Ergonomic Analysis," SAE Technical Paper 2004-01-2198, 2004, https://doi.org/10.4271/2004-01-2198.Also In
References
- Waddell G Somerville D Henderson I Newton M Objective clinical evaluation of physical impairment in chronic low back pain Spine 17 (6) 617 28 1992
- Tallroth K Alaranta H Soukka A Lumbar mobility in asymptomatic individuals J. Spinal Disord 5 (4) 481 84 1992
- Putto E Tallroth K Extension-flexion radiographs for motion studies of the lumbar spine Spine 15 (2) 107 10 1990
- Pearcy M Portek I Shepherd J The effect of low back pain on lumbar spinal movements measured by three dimensional x-ray analysis Spine 10 (2) 150 3 1985
- Saur PM Ensink FB Frese K Seeger D Hildebrandt J Lumbar range of motion: reliability and validity of the inclinometer technique in the clinical measurement of trunk flexibility Spine 21 (11) 1332 38 1996
- Mayer TG Tencer AF Kristoferson S Mooney V Use of noninvasive techniques for quantification of spinal range of motion in normal subjects and chronic low back dysfunction patients Spine 9 (6) 588 95 1984
- Gill K Krag MH Johnson GB Haugh LD Pope MH Repeatability of four clinical methods for assessment of lumbar spine motion Spine 13 (1) 50 3 1988
- Assente R Ferrigno G Pedotti A Santambrogio GC Vigano’ R AUSCAN System: A New Procedure to Evaluate Spinal Deformity Biomechanics X A Human Kinetic Publish. 1987 207 211
- Andreoni G Negrini S Mazzoleni P Ciavarro GL Santambrogio GC Pedotti A ZooMS: a non invasive analysis of global and metameric movement of the spine IFMBE Proceedings, 2 nd European and Biological Engineering Conference, Embec’02 808 09
- Andreoni G Negrini S Marocco M Molinaro MC Ciavarro GL Santambrogio GC Pedotti A ZooMS: a non invasive analysis of global and metameric movement of the spine Part I: description and validation of the method applied to the lumbar tract
- Ferrigno G Pedotti A ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing IEEE Trans Biomed Eng 1985 Nov 32 (11) 943 50
- White AA III Panjabi MM Clinical Biomechanics of the spine Lippincot-Raven Philadelphia 1990
- Ciavarro GL Andreoni G Da Re C Negrini S Santambrogio GC Pedotti A Evaluation of a rehabilitation protocol of the lumbar spine through a non invasive motion analysis system Proceedings of the 25 th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS), Cancun September 17–21 2003 1843 6
- Mangin JF Poupon C Clark C Le Bihan D Bloch I Distortion correction and robust tensor estimation for MR diffusion imaging Medical Image Analysis 6 2002 191 198
- Burkhardt S Schweikard A Burgkart R Numerical determination of the susceptibility caused geometric distortions in magnetic resonance imaging Medical Image Analysis 7 2003 221 236
- Reese TG Heid O Weisskoff RM Wedeen VJ Reduction of Eddy-Current-Induced Distortion in Diffusion MRI Using a Twice-Refocused Spin Echo Magnetic Resonance in Medicine 49 177 182 2003
- Zhang X Xiong J Model-guided derivation of lumbar vertebral kinematics in vivo reveals the difference between external marker-defined and internal segmental rotations Journal of Biomechanics 36 2003 9 17
- Alexander EJ Andriacchi TP Correcting for deformation in skin-based marker systems Journal of Biomechanics 34 2001 355 61
- Zengel F Davis BP Biomechanical analysis by chiropractic radiography: Part II. Effects of X-ray projectional distortion on apparent vertebral rotation J Manipulative Physiol Ther 1988 11 (5) 380 9