Abstract
High-intensity discharge (HID) headlamps have several advantages over tungsten-halogen headlamps, including greater light efficiency (lumens per watt) and longer life. However, from the safety point of view, the primary attraction of HID headlamps is that, because they produce more total light, they have the potential to provide more useful illumination to the driver. At the same time, there are concerns with the effects of HID illumination on perception of the colors of important objects and glare to oncoming traffic. This paper reviews research evidence that we have accumulated over the past 14 years concerning the potential benefits and drawbacks associated with the use of HID headlighting. We conclude that the evidence strongly supports the use of well-designed HID headlamps.
Recommended Content
Authors
Citation
Sivak, M., Flannagan, M., Schoettle, B., and Adachi, G., "Driving with HID Headlamps: A Review of Research Findings," SAE Technical Paper 2003-01-0295, 2003, https://doi.org/10.4271/2003-01-0295.Also In
SAE 2003 Transactions Journal of Passenger Cars - Mechanical Systems
Number: V112-6; Published: 2004-09-15
Number: V112-6; Published: 2004-09-15
References
- Alferdinck, J.W.A.M. Varkevisser, J. 1991 Discomfort glare from D1 headlamps of different size Soesterberg, The Netherlands TNO Institute for Perception
- Blaauw, G.J. 1984 Car driving as a supervisory control task Soesterberg, The Netherlands Institute for Perception TNO
- Bullough, J.D. Fu, Z. Van Derlofsky, J. 2002 Discomfort and disability glare from halogen and HID headlamp systems SAE Technical Paper Series No. 2002-01-0010 Warrendale, PA Society of Automotive Engineers
- Flannagan, M.J. 1999 Subjective and objective aspects of headlamp glare: Effects of size and spectral power distribution Ann Arbor, MI The University of Michigan Transportation Research Institute
- Flannagan, M.J. Sivak, M. Battle, D.S. Sato, T. Traube, E.C. 1993 Discomfort glare from high-intensity discharge headlamps: Effects of context and experience Ann Arbor, MI The University of Michigan Transportation Research Institute
- Flannagan, M. Sivak, M. Ensing, M. Simmons, C.J. 1989 Effect of wavelength on discomfort glare from monochromatic sources Ann Arbor, MI The University of Michigan Transportation Research Institute
- Flannagan, M.J. Sivak, M. Gellatly, A.W. 1991 Joint effects of wavelength and ambient luminance on discomfort glare from monochromatic and bichromatic sources Ann Arbor, MI The University of Michigan Transportation Research Institute
- Flannagan, M.J. Sivak, M. Gellatly, A.W. Luoma, J. 1992 A field study of discomfort glare from high-intensity discharge headlamps Ann Arbor, MI The University of Michigan Transportation Research Institute
- Flannagan, M.J. Sivak, M. Gellatly, A.W. Luoma, J. 1992 Ranges of stop sign chromaticity under tungsten-halogen and high-intensity discharge illumination Ann Arbor, MI The University of Michigan Transportation Research Institute
- Grimm, M. Hamm, M. 2001 ECE headlamp performance status and potential for improvement Proceedings of the Conference on Progress in Automobile Lighting 348 354 Darmstadt, Germany Darmstadt University of Technology
- Kantowitz, B. Sorkin, R.D. 1983 Human factors New York Wiley
- McLean, J.R. Hoffmann, E.R. 1971 Analysis of drivers' control movements Human Factors 13 407 418
- Manz, K. 2001 The influence by size of headlamp on discomfort glare Proceedings of the Conference on Progress in Automobile Lighting 618 634 Darmstadt, Germany Darmstadt University of Technology
- Olson, P.L. Sivak, M. 1984 Discomfort glare from automobile headlights Journal of the Illuminating Engineering Society 13 296 303
- Perel, M. Olson, P. Sivak, M. Medlin, J.W. 1983 Motor vehicle forward lighting SAE Technical Paper Series No. 830567 Warrendale, PA Society of Automotive Engineers
- Schoettle, B. Sivak, M. Flannagan, M.J. Adachi, G. 2002 The illuminated surface areas of HID and tungsten-halogen headlamps in the U.S. Ann Arbor, MI The University of Michigan Transportation Research Institute
- Schumann, J. 2000 Post-mounted delineators and perceptual cues for long-range guidance during night driving Ann Arbor, MI The University of Michigan Transportation Research Institute
- Sivak, M. Flannagan, M.J. Ensing, M. Simmons, C.J. 1991 Discomfort glare is task dependent International Journal of Vehicle Design 12 152 159
- Sivak, M. Flannagan, M.J. Gellatly, A.W. Luoma, J. 1992 Subjective preferences for the red color of stop signs: Implications for the design of high-intensity discharge headlamps Color Research and Application 17 356 360
- Sivak, M. Flannagan, M.J. Schoettle, B. Mefford, M.L. 2002 Driving performance with and preference for HID headlamps Ann Arbor, MI The University of Michigan Transportation Research Institute
- Sivak, M. Flannagan, M.J. Schoettle, B. Nakata, Y. 2002 Performance of the first generation of HID headlamps in the U.S. Ann Arbor, MI The University of Michigan Transportation Research Institute
- Sivak, M. Flannagan, M.J. Traube, E.C. Battle, D.S. Sato, T. 1994 Evaluations of in-traffic performance of high-intensity discharge headlamps Lighting Research and Technology 26 181 188
- Sivak, M. Simmons, C.J. Flannagan, M.J. 1990 Effect of headlamp area on discomfort glare Lighting Research and Technology 22 49 52
- Sivak, M. Simmons, C.J. Flannagan, M.J. 1991 Colours of retroreflective sign materials when illuminated by high-intensity-discharge headlamps International Journal of Vehicle Design 12 284 295
- Sullivan, J. M. Flannagan, M. J. 2001 Characteristics of pedestrian risk in darkness Ann Arbor, MI The University of Michigan Transportation Research Institute