Real-Time Measurement of Flow Quality in CCOT Systems
Technical Paper
2002-01-0508
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Systematic design of mobile air-conditioning system components in R134a systems has been hampered by inaccurate knowledge of the flow quality, especially the amount of liquid returned to the compressor. The thermodynamic quality is typically used, but it is somewhat unreliable due to the large percentage of miscible compressor oil circulating with the refrigerant. A technique for measuring the flow quality in the refrigeration loop based on phase segregation and recombination has been developed and verified. The refrigerant quality has been deduced with the aid of standard sampling methods for measuring the percentage of oil in circulation. Hence, the relative contributions of all three components of the flow have been measured. The method is suitable for relative evaluation of component performance on a test stand. The method has been applied to measuring evaporator discharge quality at standard conditions and to quantifying accumulator liquid carryover. Measured flow quality at the accumulator outlet varied from 77-88%, corresponding to refrigerant quality of 83-93%. The flow quality measurement technique presented will be used to help determine the relative effects of different accumulator designs on system performance - improving accumulator design and speeding up the time to develop new products.
Recommended Content
Authors
Citation
McGregor, I., Dickson, T., Hwang, D., and Kawaji, M., "Real-Time Measurement of Flow Quality in CCOT Systems," SAE Technical Paper 2002-01-0508, 2002, https://doi.org/10.4271/2002-01-0508.Also In
SAE 2002 Transactions Journal of Passenger Cars - Mechanical Systems
Number: V111-6; Published: 2003-09-15
Number: V111-6; Published: 2003-09-15
References
- ASHRAE Handbook 1998 Refrigeration, American Society of Heating, Refrigeration, and Air-Conditioning Engineers, Inc. Atlanta
- Jacobs, M. L. Scheideman, F. C. Kazem, S. M. Macken, N. A. 1976 “Oil Transport by Refrigerant Vapor” ASHRAE Transactions 82 318 329
- Hwang, D. H. 2001 “Flow Quality Measurement Based on Stratification of Flow in Nitrogen Gas-Water and HFC-134a-PAG Oil Two-Phase Flow Systems” University of Toronto
- Abdul-Razzak, A. Shoukri, M. Chang, J. S. 1995 “Measurement of Two-Phase Refrigerant Liquid-Vapor Mass Flow Rate” Final Report, ASHRAE 722-TRP Research Project
- Solberg, J. Miller, N. R. Hrnjak, P. 2000 “A Sensor for Estimating the Liquid Mass Fraction of the Refrigerant Exiting an Evaporator” SAE Technical Paper Series SAE 2000 World Congress Detroit, Michigan 2000-01-0976
- Kim, Y. C. O'Neal, D. L. 1994 “The Effect of Oil on the Two-Phase Critical Flow of Refrigerant 134a through Short Tube Orifices” Int. J. Heat Mass Transfer 37 9 1377 1385