Comparative Consistency of Univariate Measures from Traditional and 3-D Scan Anthropometry
Technical Paper
2000-01-2145
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Traditional and three-dimensional (3-D) scan tools capture anthropometric information in different ways. It is not surprising that measurements from each can have different values. Some possible reasons for differences are tissue compression when using traditional tools, and the difficulty of precise replication of traditional measures using computer algorithms. Even with precise replication of traditional methods, there may be consistent differences in magnitude that can be compensated for.
Once compensation factors have been determined, people who have only traditional tools available can also use measurements extracted from 3-D scan data, and people who use 3-D scans can relate extracted measurements to historical data. With adjustments, the results of either method can be used interchangeably.
This research compares the consistency of traditional and 3-D scan anthropometry for a small set of traditional univariate measures. It also examines the agreement between the two methodologies when they are adjusted by the mean difference. The intent is to better understand the sources of difference between measures and to begin developing a general technique for creating algorithms that produce similar results between traditional and scan methods.
Recommended Content
Authors
Topic
Citation
Perkins, T., Burnsides, D., Robinette, K., and Naishadham, D., "Comparative Consistency of Univariate Measures from Traditional and 3-D Scan Anthropometry," SAE Technical Paper 2000-01-2145, 2000, https://doi.org/10.4271/2000-01-2145.Also In
SAE 2000 Transactions Journal of Passenger Cars - Mechanical Systems
Number: V109-6; Published: 2001-09-15
Number: V109-6; Published: 2001-09-15
References
- Burnsides, D. B. Files, P. M. Whitestone, J. J. 1996 Integrate 1.25: A Prototype for Evaluating Three-Dimensional Visualization, Analysis and Manipulation Functionality Armstrong Laboratory, Crew Systems Directorate, Human Engineering Division Wright-Patterson Air Force Base, OH
- Daanen, H. Brunsman, M. Taylor, S. 1997 Absolute Accuracy of the Cyberware WB4 Whole Body Scanner Armstrong Laboratory, Crew Systems Directorate, Human Engineering Division Wright-Patterson Air Force Base, OH
- Bradtmiller, B. Gross, M. E. 1999 3D Whole Body Scans: Measurement Extraction Software Validation Proceedings of the SAE International Digital Human Modeling for Design and Engineering International Conference and Exposition The Netherlands
- Clauser, C. Tebbetts, I. Bradtmiller, B. McConville, J. Gordon, C. C. 1988 Measurer's Handbook: U.S. Army Anthropometric Survey, 1987-1988 U.S. Army Natick Research, Development and Engineering Center Natick, MA 310 312