Abstract
This study describes the construction and evaluation of a low energy house which should be in harmony with the environment and also be assisted by hybrid natural energy resources and unused energy. An experimental house with ground source heat pump (GSHP) was built in Hokkaido University, Japan in March, 1997. As a result of experiments, it was shown that approx. 80 % of the total energy was provided from PV modules, solar collectors, underground and exhaust heat. Annual energy consumption was 12.5 % of typical house’s one in Hokkaido. This report describes an outline of the low energy house and experimental energy balance.
Authors
- Yasuhiro Hamada - Graduate School of Engineering, Hokkaido University, JAPAN
- Kiyoshi Ochifuji - Graduate School of Engineering, Hokkaido University, JAPAN
- Makoto Nakamura - Graduate School of Engineering, Hokkaido University, JAPAN
- Katsunori Nagano - Graduate School of Engineering, Hokkaido University, JAPAN
Citation
Hamada, Y., Ochifuji, K., Nakamura, M., and Nagano, K., "Energy Balance of Low Energy House with Ground Source Heat Pump in Hokkaido," SAE Technical Paper 1999-01-2667, 1999, https://doi.org/10.4271/1999-01-2667.Also In
References
- Nagano, K. Nakamura, M. Hamada, Y. Yokoyama, S. Ochifuji K. et al.: Low Energy House in Hokkaido, 4th Japan/Canada Housing R&D Workshop Proceedings Nov. 1997 V168 V171
- Hamada, Y. Ochifuji, K. Nakamura M. Nagano: K. Energy Balance of Low Energy House with GHPS in Hokkaido, Proceedings of The 2nd Stockton International Geothermal Conference-Hybrid System Mar. 1998 221 230
- Hamada, Y. Ochifuji, K. Nagano K. Nakamura: M. Study on the Heating and Cooling by Longterm Heat Storage with Underground Vertical Utubes Proceedings of 7th International Conference on Thermal Energy Storage-MEGASTOCK ’ 97 Jun. 1997 37 42
- Nagano, K. Ochifuji, K. Nakamura M. Hamada: Y. Study on the Ground Heat Extraction utilizing Horizontal Earth Coils, Proceedings of 7th International Conference on Thermal Energy Storage- MEGASTOCK ’ 97 Jun. 1997 229 234
- Ochifuji, K. Nakamura M. Hamada: Y. Groundsource Heat Pump Systems in Japan, IEA Heat Pump Centre Newsletter, 17-1 Mar 1999 13 14
- Nagano, K. Nakamura, M. Ochifuji K. et al.: Investigation on Domestic Energy Consumption in Sapporo SHASE Annual Technical Meeting (Oct 1993 261 268