This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
3D Whole Body Scans: Measurement Extraction Software Validation
Technical Paper
1999-01-1892
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Three-dimensional (3D) whole body scanners provide an opportunity for collecting large quantities of precise point data on human forms. However, product designers will likely always need some access to traditional point-to-point dimensional measurements. These measurements can also be obtained from the 3D whole body scanner if appropriate software is developed. This project describes a validation test for a collection of software tools designed to extract traditional dimensions from 3D whole body scans. To validate the software we scanned 123 male and female subjects on a Cyberware WB4 whole body scanner. Subjects were also measured for point-to-point dimensions using traditional instruments. We compared the mean absolute differences between traditional and software measurements to interobserver error data collected in a large traditional anthropometric survey (ANSUR), and to various criteria specific to garment applications. While the extracted measurements were generally acceptable using the garment standards for comparison, the differences were generally larger than ANSUR observer error.
Recommended Content
Technical Paper | Comparative Consistency of Univariate Measures from Traditional and 3-D Scan Anthropometry |
Technical Paper | Evaluation of Accuracy in Traditional and 3D Anthropometry |
Journal Article | Truck Instep Evaluation Using a Sample of Manikins |
Authors
Citation
Bradtmiller, B. and Gross, M., "3D Whole Body Scans: Measurement Extraction Software Validation," SAE Technical Paper 1999-01-1892, 1999, https://doi.org/10.4271/1999-01-1892.Also In
References
- Cameron, Noel 1984 The Measurement of Human Growth Croom Helm London, England
- Clauser, Charles Tebbetts Ilse Bradtmiller Bruce McConville John Gordon Claire 1988 Measurer's Handbook: U.S. Army Anthropometric Survey, 1987-1988 Technical Report NATICK/TR-88-043 (AD A164 637), U.S. Army Natick Research, Development and Engineering Center Natick, Massachusetts
- Gordon, Claire C. Bradtmiller Bruce Clauser Charles E. Churchill Thomas McConville John T. Tebbetts Ilse Walker Robert A. 1989 1987-1988 Anthropometric Survey of U.S. Army Personnel: Methods and Summary Statistics Technical Report NATICK/TR-89-044, U.S. Army Natick Research, Development and Engineering Center Natick, Massachusetts