J968/1_199105 DIESEL INJECTION PUMP TESTING—PART 1: CALIBRATING NOZZLE AND HOLDER ASSEMBLIES

Revised

05/01/1991

Features
Issuing Committee
Scope
Content
This part of SAE J968 specifies two types of calibrating nozzle and holder assemblies intended for the testing and setting of diesel injection pumps on test benches.
It applies to:
  1. a
    A calibrating nozzle and holder assembly with a single hole orifice plate;
  2. b
    A calibrating nozzle and holder assembly with a delay pintle type nozzle.
The approximate range of the calibrating nozzle and holder assembly is up to:
  1. a
    300 mm3/stroke with the single hole orifice plate;
  2. b
    150 mm3/stroke with the delay pintle type nozzle.
Setting and maintenance requirements are specified in ISO 4008/3.
Meta TagsDetails
DOI
https://doi.org/10.4271/J968/1_199105
Pages
14
Citation
SAE International Recommended Practice, DIESEL INJECTION PUMP TESTING—PART 1: CALIBRATING NOZZLE AND HOLDER ASSEMBLIES, SAE Standard J968/1_199105, Revised May 1991, Issued August 1966, https://doi.org/10.4271/J968/1_199105.
Additional Details
Publisher
Published
May 1, 1991
Product Code
J968/1_199105
Content Type
Recommended Practice
Status
Revised
Language
English