J211/1_202208 Instrumentation for Impact Test Part 1 - Electronic Instrumentation

Revised

08/19/2022

Features
Issuing Committee
Scope
Content
This SAE Recommended Practice outlines a series of performance recommendations, which concern the whole data channel. These recommendations are not subject to any variation and all of them shall be adhered to by any agency conducting tests to this practice. However, the method of demonstrating compliance with the recommendations is flexible and can be adapted to suit the needs of the particular equipment the agency is using.
It is not intended that each recommendation be taken in a literal sense, as necessitating a single test to demonstrate that the recommendation is met. Rather, it is intended that any agency proposing to conduct tests to this practice shall be able to demonstrate that if such a single test could be and were carried out, then their equipment would meet the recommendations. This demonstration shall be undertaken on the basis of reasonable deductions from evidence in their possession, such as the results of partial tests.
In some systems, it may be necessary to divide the whole channel into subsystems, for calibration and checking purposes. The recommendations have been written only for the whole channel, as this is the sole route by which subsystem performances affect the quality of the output. If it is difficult to measure the whole channel performance, which is usually the case, the test agency may treat the channel as two or more convenient subsystems. The whole channel performance could then be demonstrated on the basis of subsystem results, together with a rationale for combining the subsystem results together.
SAE J211-1 of this SAE Recommended Practice covers electronic instrumentation. SAE J211-2 covers photographic instrumentation.
Rationale
Content
In an effort to improve overall accuracy of data collection, SAE J211 is being revised to add additional sensor types, improve the definition of the forces and to recommend that data collection move to 20K samples per a second and 16-bit resolution. Adding a definition for CFC20. Continued ongoing effort to harmonize with ISO 6487.
Meta TagsDetails
DOI
https://doi.org/10.4271/J211/1_202208
Pages
29
Citation
SAE International Recommended Practice, Instrumentation for Impact Test Part 1 - Electronic Instrumentation, SAE Standard J211/1_202208, Revised August 2022, Issued October 1970, https://doi.org/10.4271/J211/1_202208.
Additional Details
Publisher
Published
Aug 19, 2022
Product Code
J211/1_202208
Content Type
Recommended Practice
Status
Revised
Language
English