J1113/3_201008 Conducted Immunity, 250 kHz to 400 MHz, Direct Injection of Radio Frequency (RF) Power

Canceled

08/05/2010

Features
Issuing Committee
Scope
Content
This part of SAE J1113 specifies the direct RF power injection test method and procedure for testing electromagnetic immunity of electronic components for passenger cars and commercial vehicles. The electromagnetic disturbances considered in this part of SAE J1113 are limited to continuous, narrowband conducted RF energy.
This test method is applicable to all DUT leads except the RF reference ground. The test provides differential mode excitation to the DUT.
Immunity measurements of complete vehicles are generally only possible by the vehicle manufacturer. The reasons, for example, are high costs of a large absorber-lined chamber, preserving the secrecy of prototypes or the large number of different vehicle models. Therefore, for research, development, and quality control, a laboratory measuring method for components shall be applied by the manufacturer. This method is suitable over the frequency range of 250 kHz to 400 MHz.
This direct RF power injection test is particularly effective when used as part of the engineering development of the electronic component (at the prototype PCB level) where the line by line diagnostic capabilities of this test facilitate cost-effective circuit board level improvements in the RF immunity performance of the module or component
Rationale
Content
SAE J1113-3 is being cancelled in favor of ISO 11452-7.
Meta TagsDetails
DOI
https://doi.org/10.4271/J1113/3_201008
Pages
10
Citation
SAE International Technical Standard, Conducted Immunity, 250 kHz to 400 MHz, Direct Injection of Radio Frequency (RF) Power, SAE Standard J1113/3_201008, Cancelled August 2010, Issued November 1995, https://doi.org/10.4271/J1113/3_201008.
Additional Details
Publisher
Published
Aug 5, 2010
Product Code
J1113/3_201008
Content Type
Technical Standard
Status
Canceled
Language
English

Revisions