The performance of a centrifugal compressor with a range of low solidity diffuser vanes is discussed. The effect of vane leading and trailing edge angle was investigated while maintaining a basic design with 10 vanes and a solidity of 0.69. The diffuser vanes were designed with a circular arc camberline and a specified leading edge angle. The trailing edge angle was varied by specifying a range of angles through which the vanes turned. Vanes with leading edge angles of 65°, 70°, 75°, and 80° were considered together with vane turning angles of 10°, 15° and 20°. All results are compared with those obtained with the standard vaneless diffuser configuration. Despite the low solidity configuration none of the vane designs provided a broad operating range and it would be necessary to deploy a variable geometry arrangement. Vane designs with a leading edge angle of 65° showed a premature surge, and whilst vane designs with a leading edge angle of 80° suppressed surge poor performance occurred at high flow rates. It is shown that the modification of the vane trailing edge angle led to poor matching of the diffuser discharge flow conditions with those required by the collecting volute.
Recommended Content
Authors
Topic
Citation
Eynon, P. and Whitfield, A., "Performance of a Turbocharger Compressor With a Range of Low Solidity Vaned Diffusers," SAE Technical Paper 980772, 1998, https://doi.org/10.4271/980772.Also In
References
- Senoo Y. “Low solidity cascade diffusers for wide flow range centrifugal blowers,” ASME Paper No. 83-GT-3 1983
- Osborne C. Sorokes J.M. “The application of low solidity diffusers in centrifugal compressors,” ASME Conference on Non-Rotating Turbomachinery Components 1988 69 89 101
- Sorokes J.M. Welch J.P. “Experimental results on a rotatable low solidity vaned diffuser,” ASME Paper No. 92-GT-19 1992
- Hohlweg W.C. Direnzi G.L Aungier R.H. “Comparison of conventional and low solidity vaned diffusers,” ASME Paper No. 93-GT-98 1993
- Harada H. Goto M. “Numerical and experimental studies of single and tandem low solidity cascade diffusers in a centrifugal compressor” ASME Paper No. 93-GT-108 1993
- Jiang P.M. Whitfield A. “Investigation of vaned diffusers as a variable geometry device for application to turbocharger compressors,” Proceedings of the Institute of Mechanical Engineers, Part D: Journal of Automobile Engineering 206 209 220 1992
- Eynon P. A. Whitfield A. “The effect of low solidity vaned diffusers on the performance of a turbocharger compressor” Proc. Instn Mech Engrs 211 325 339 1997
- Fisher F. B. “Application of map width enhancement devices to turbocharger compressor stages” SAE Paper No. 880794 1988 earthmoving Industry Conference Peroria, Illinois