Potable Water Treatment and Transfer from Shuttle to Mir
Annotation ability available
Sector:
Language:
English
Abstract
To satisfy a requirement to supply water to Mir station, a process for treating iodinated water on the Shuttle was developed and implemented. The treatment system consists of packed columns for removing iodine and a syringe-based injection system for adding ionic silver, the biocide used in Mir water. Technical and potable grade water is produced and transferred in batches using collapsible 44-liter contingency water containers (CWCs). Silver is added to the water via injection of a solution from preloaded syringes. Minerals are also added to water destined for drinking. During the previous four Shuttle-Mir docking missions a total of 2781 liters (735 gallons) of water produced by the Shuttle fuel cells was processed using this method and transferred to Mir.
To verify the quality of the processed water, samples were collected during flight and returned for chemical analysis. Results show that iodine and related species were removed effectively by the activated carbon and ion exchange treatment system. Target concentrations of silver, fluoride, calcium and magnesium were reproducibly obtained. A discussion of problems encountered during the first flight of the treatment system, and the changes made for subsequent flights, are presented. Potential future applications of this hardware for the International Space Station are also discussed.
Authors
Topic
Citation
Mudgett, P., Schultz, J., Packham, N., Veselka, D. et al., "Potable Water Treatment and Transfer from Shuttle to Mir," SAE Technical Paper 972461, 1997, https://doi.org/10.4271/972461.Also In
References
- NASA Specification “Fluid Procurement and Use Control,” Rev F, Change 61 June 1996
- Protasov Nickolai RSC-Energia November 1995 February 1997
- Samsonov, N.M. et al. “Water supply based on water reclamation from humidity condensate and urine on a space station.” 26th International Conference on Environmental Systems, SAE Paper 961408 Monterey, CA 1996
- Pierre, L. M. et al. “Collection and Chemical Analysis of Reclaimed Water and Condensate from the Mir Space Station.” 26th International Conference on Environmental Systems, SAE Paper 961569 Monterey, CA 1996
- Gibbons, R.E. et al. “Recent Experiences with Iodine Water Disinfection in Shuttle.” 20th lntersociety Conference on Environmental Systems, SAE Paper 901356 Williamsburg, VA 1990
- Molina Daniel Rockwell November 1996
- Fields, N.D. Shuttle Postflight Potable Water Sample Reports KSC Biomedical and Environmental Laboratories Bionetics Corporation 1991-1994
- Standard Test Method for Determination of Iodine Number of Activated Carbon, Method D4607 American Society for Testing and Materials (ASTM) 1994
- Sauer, R.L. Westover, J.B. “The Potable Water System in Skylab.” Intersociety Conference on Environmental Systems, ASME Paper74-ENAs-17 Seattle, WA 1974