The effect of MMT on the OBD-II catalyst efficiency monitor has been investigated. The results conclusively show that manganese which is deposited onto the catalyst during the combustion of MMT- containing fuel provides for an increased level of catalyst oxygen storage capacity. This added oxygen storage was found to result in a reduced rear EGO sensor response and caused malfunctioning catalysts to be incorrectly diagnosed by the OBD-II catalyst efficiency monitor.