Pulsed Single-Blow Regenerator Testing

929386

08/03/1992

Event
27th Intersociety Energy Conversion Engineering Conference (1992)
Authors Abstract
Content
A pulsed single-blow method has been developed for testing of Stirling regenerator materials performance. The method uses a tubular flow arrangement with a steady gas flow passing through a regenerator matrix sample that packs the flow channel for a short distance. A wire grid heater spanning the gas flow channel is used to heat a plug of gas by approximately 2 K for approximately 350 ms. Foil thermocouples monitor the gas temperature entering and leaving the sample. Data analysis based on a 1-D incompressible-flow thermal model allows the extraction of Stanton number. A figure of merit involving heat transfer and pressure drop is used to present results for steel screens and steel felt. The observations show a lower figure of merit for the materials tested than is expected based on correlations obtained by other methods.
Meta TagsDetails
DOI
https://doi.org/10.4271/929386
Pages
5
Citation
Oldson, J., Knowles, T., and Rauch, J., "Pulsed Single-Blow Regenerator Testing," SAE Technical Paper 929386, 1992, https://doi.org/10.4271/929386.
Additional Details
Publisher
Published
Aug 3, 1992
Product Code
929386
Content Type
Technical Paper
Language
English