Effect of the Grid Aperture on the Operation of the Cs-Ba Tacitron Inverter

929240

08/03/1992

Event
27th Intersociety Energy Conversion Engineering Conference (1992)
Authors Abstract
Content
Experiments were conducted in which an inverter was configured by connecting two Cs-Ba tacitrons, with alternating voltage grid control, in a push-pull mode. The inverter operated at a discharge current of up to 3.5 A, collector voltage of 25 V, conduction voltage drop of 3 - 3.5 V, and modulation frequencies up to 20 kHz. When the grid aperture diameter was reduced from 0.8 to 0.4 mm, it was possible to operate the inverter at discharge currents up to 13.5 A, collector voltage of 24 V and a conduction voltage drop of 4 V.
Meta TagsDetails
DOI
https://doi.org/10.4271/929240
Pages
5
Citation
El-Genk, M., Kaibyshev, V., Murray, C., Wernsman, B. et al., "Effect of the Grid Aperture on the Operation of the Cs-Ba Tacitron Inverter," SAE Technical Paper 929240, 1992, https://doi.org/10.4271/929240.
Additional Details
Publisher
Published
Aug 3, 1992
Product Code
929240
Content Type
Technical Paper
Language