This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
3D-Design, Fabrication and Metrological Characteristics for Knee Meniscus Replacement Prototype using Proposed Polymeric Material
Technical Paper
2016-01-0509
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Due to the accidents of the motor vehicles and the osteoporosis, many people enface a lot of troubles and sometimes necessities for replacement of their knee joints. Practically, mechanical properties and surface characteristics of Total Knee Replacement (TKR) are very important parameters for improving the performance response in human. The meniscus is a small element and an essential part of the TKR. The knee meniscus has special feature allows the easy dynamic loading and motion of leg and foot with high accuracy and good balance. Therefore design and analysis of the geometrical shape for the meniscus replacement is worthy to be studied. In this paper, a proposed design using a computer software package has been presented. 3D simulation analyses of a variety of meniscus thickness and different materials under different loads are investigated. The compression stresses and surfaces deformations are determined numerically through the Finite Element Analysis (FEA) technique. A developed polymeric material reinforced by Carbon Nanotube particles (CNTs) is discussed. The thickness of meniscus for both the tibia-direction (Ht) and the femur-direction (Hf) has insignificant effect on the compression stresses and surface deformation. While, the developed material of 50 wt.% UHMWPE, 48wt.% HDPE and 2wt.% CNTs showed the lowest deformation on the meniscus surface. In addition, a proposed prototype of a polymeric material for the design of the meniscus has been manufactured by a CNC machine. The dimension trueness and accuracy of fabricated prototype as metrological characteristics for knee meniscus replacement are also evaluated. Moreover, uncertainty estimation for dimensional measurement has been studied and confirmed the confidence degree of the fabrication accuracy for the proposed prototype.
Recommended Content
Authors
Citation
Ali, S., Zahwi, S., Mabrok, M., and Azzam, B., "3D-Design, Fabrication and Metrological Characteristics for Knee Meniscus Replacement Prototype using Proposed Polymeric Material," SAE Technical Paper 2016-01-0509, 2016, https://doi.org/10.4271/2016-01-0509.Also In
References
- Department of Transportation (US), National Highway Traffic Safety Administration )NHTSA) Traffic Safety Facts 2012: Pedestrians Washington (DC) NHTSA April 2014 http://www-nrd.nhtsa.dot.gov/Pubs/811888.pdf
- Takahashi , Y. , Okamoto , M. , Akiyama , A. , and Kikuchi , Y. Estimation of Knee Ligament Injury Measures for a Pedestrian Dummy SAE Int. J. Passeng. Cars - Mech. Syst. 2 1 1116 1124 2009 10.4271/2009-01-1212
- Cao , L. , Zhang , K. , Lv , X. , and Yan , L. Improvement and Validation of Hybrid III Dummy Knee Finite Element Model SAE Int. J. Mater. Manf. 8 3 640 645 2015 10.4271/2015-01-0449
- Kitagawa , Y. , Hasegawa , J. , Yasuki , T. , Iwamoto , M. , and Miki , K. A Study of Knee Joint Kinematics and Mechanics using a Human FE Model SAE Technical Paper 2005-22-0006 2005
- Shenoy R , Pastides PS , Nathwani D Biomechanics of the Knee and TKR The Knee Orthopaedics and Trauma 27 6 364 371 Dec. 2013
- Hamilton DF , Gaston P , Simpson AHRW Single Radius of Curvature Implant Design Enhances Power Output Following Total Knee Arthroplasty Journal Bone Joint Surg Br 2012 94-B 2012
- Fening Stephen D. The Creation of Solid Models of the Human Knee From Magnetic Resonance Images MSc thesis College of Engineering and Technology Ohio University, USA June 2003
- Ziyue Liu and Fuzhong Wang The Establishment of Three-Dimensional Model of Human Knee Joint Journal of Software Engineering and Applications 8 1 1 5 2015
- Wataya Celio H. , , Jardini Andre L.M. , Pascoal Gustavo H. de L. , Vanessa P.B. and Zavaglia Cecilia A.C. PVA Meniscus Development by Rapid Prototyping (RP) Proceedings of the 21st Brazilian Congress of Mechanical Engineering Natal, RN, Brazil 24-28 October 2011
- Katja Bloecker , Martin Englund , Wolfgang Wirth , Martin Hudelmaier , Rainer Burgkart , Frobell Richard B and Felix Eckstein Size and Position of the Healthy Meniscus, and Its Correlation with Sex, Height, Weight, and Bone Area- a Cross-sectional Study BMC Musculoskeletal Disorders 12 248 1471 1474 2011
- Ariumi A. , Sato T. , Watanabe S. , Tanifuji O. and Omori G. Three-Dimensional Assessment of the Mechanical Axis Crossing Point of the Knee Joint Line in the Weight-bearing Standing Position in Healthy Elderly Subjects 8th Combined Meeting of Orthopedic Research Societies Italy 13-16 October 2013
- Wijdicks Coen A. , Kennedy Nicholas I. , Goldsmith Mary T. , Devitt Brian M. , Michalski Max P. , roen Asbjorn A , Lars Engebretsen and LaPrade Robert F. Kinematic Analysis of the Posterior Cruciate Ligament, Part 2: A Comparison of Anatomic Single-Versus Double-Bundle Reconstruction American Journal of Sports Medicine 41 12 2828 38 2013
- Cheng-Kung Cheng , McClean Colin J. , Lai Yu-Shu , Chen Wen-Chuan , Huang Chang-Hung , Lin Kun-Jhih , and Chang Chia-Ming Biomechanical Considerations in the Design of High-Flexion Total Knee Replacements Scientific World Journal 2014 1 6 May 2014
- Judy Village , Greig , Michael , Zolfaghari S. , Salustri F. , and Neumann W. P. Adapting Engineering Design Tools to Include Human Factors IIE Transactions on Occupational Ergonomics and Human Factors 2 1 14 2014
- Gray JC Neural and Vascular Anatomy of the Menisci of the Human Knee J Orthop Sports Phys Ther 29 1 23 30 1999
- Ali Salah H.R. and Azam Badr S.N. Mechanical, Tribological Properties and Surface Characteristics of Developed Polymeric Materials Reinforced by CNTs SAE International Journal of Fuels and Lubricants 8 1 35 40 2015
- Ali Salah H.R. , Almaatoq M.M.A. and Abdalla S.A. Classifications, Surface Characterization and Standardization of Nanobiomaterials Int. Journal of Engineering and Tech. 2 3 187 199 2013
- Karelse A , Kegels L , De Wilde L. The Pillars of the Scapula Clin Anat. 20 392 399 2007
- Ali Salah H.R. , Almaatoq Marwah M.A. and Mohamed Abdalla S.A. Recent Progress in Nanometrology Techniques for Object Characterization Int. Journal of Engineering Research and Applications (IJERA) 3 4 1343 1366 2013
- Musib M. K. A Review of the history and Role of UHMWPE as Component in Total Joint Replacements Int. Journal of Biological Engineering 1 1 6 10 2011
- Stein , H. L. Ultrahigh molecular weight polyethylenes (UHMWPE) Engineered Materials Hand Book 167 171 1998
- Vikas Mittal Polymer Nanotube Nanocomposites: Synthesis, Properties and Applications Hand Book John Wiley & Sons Co. 2010
- Ali Salah H.R. Developed Design of Humeral Head Replacement using 3D Surface Mapping Latvian Journal of Physics and Technical Sciences,(JPT),Physics in Engineering 51 6 41 55 2014
- Ali Salah H.R. , Bedewy M.K. , Etman M.A. , Khalil H.A. and Azzam B.S. Morphology and Properties of Polymer Matrix Nanocomposites Int. Journal of Metrology and Quality Eng. 1 01 33 39 2010
- Ali Salah H.R. and Zahwi Sarwat Z.A. CT Measurement and Geometrical Shape Analysis for Human Shoulder Glenoid International Review of Mechanical Engineering (I.RE.M.E.) 8 2 370 378 March 2014
- International Standard Organization: Geometrical Product Specifications (GPS) - Acceptance and reverification tests for Coordinate Measuring Machines (CMM) - Part 2: CMMs used for Measuring Size ISO 10360-2 2 nd 15 12 2001
- Ali , Salah H.R. Performance Investigation of CMM Measurement Quality using Flick Standard Journal of Quality and Reliability Engineering (JQRE) 2014 1 11 July 2014
- Vicki Barwick and Elizabeth Prichard Terminology in Analytical Measurement- Introduction to VIM 3 978-0-948926-29-7 2011
- Pierre Squara , Michael Imhoffand , and Maurizio Cecconi Metrology in Medicine: From Measurements to Decision, with Specific Reference to Anesthesia and Intensive Care Official journal of the International Anesthesia Research Society: Anesthesia & Analgesia 120 1 2015
- BIPM, Joint Committee for Guides in Metrology Guide to the expression of uncertainty in measurement (GUM) 2008