Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance
Technical Paper
2014-01-0706
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
Lubricant in compressor usually flows out with refrigerant. Thus, it is evitable for lubricant to be present in the heat exchanger, which significantly affects the heat exchanger performance. This paper is to investigate the effects of PAG oil on R134a distribution in the microchannel heat exchanger (MCHX) with vertical headers and to provide a tool to model R134a (with oil) distribution and its effects on MCHX capacity. The flow configuration in MCHX under the heat pump mode of the reversible system is mimicked in the experimental facility: refrigerant-oil mixture is fed into the test header from the bottom pass and exits through the top pass. It is found that a small amount of oil (OCR=0.5%) worsen the distribution. But further increasing OCR to 2.5% and 4.7%, the distribution becomes better. However, in a multi-pass microchannel heat exchanger model (considering oil effects), though the distribution is better and the capacity is closer to the uniform distribution case, the MCHX capacity decreases with respect to OCR because oil affects the heat transfer and pressure drop in the microchannel heat exchanger.
Recommended Content
Authors
Citation
Zou, Y., Li, H., and Hrnjak, P., "Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance," SAE Technical Paper 2014-01-0706, 2014, https://doi.org/10.4271/2014-01-0706.Also In
References
- Fei , P. , Cantrak , D. , and Hrnjak , P. Refrigerant Distribution in the Inlet Header of Plate Evaporators SAE Technical Paper 2002-01-0948 2002 10.4271/2002-01-0948
- Vist , S. and Pettersen , J. Two-phase flow distribution in compact heat exchanger manifolds Experimental Thermal Fluid Science 28 209 215 2004
- Webb , R.L. and Chung , K. Two-phase flow distribution to tubes of parallel flow air-cooled heat exchangers Heat Transfer Engineering 26 4 3 18 2005
- Bowers , C.D. , Newell , T.A. , and Hrnjak , P.S. Experimental Investigation of Two-Phase Refrigerant Distribution in a Microchannel Manifold Technical Report TR-245 Air Conditioning and Refrigeration Center, Univ. Illinois Urbana-Champaign 2006
- Hwang , Y. , Jin , D.H. , and Radermacher , R. Refrigerant distribution in minichannel evaporator manifolds HVAC&R Research 13 4 543 555 2007
- Watanabe , M. , Katsuta , M. , and Nagata , K. General characteristics of two-phase flow distribution in a multipass tube Heat Transfer-Japanese Research 24 32 44 1995
- Cho , H. and Cho , K. Mass flow rate distribution and phase separation of R-22 in multi-microchannel tubes under adiabatic condition Microscale Thermophysical Engineering 8 2 129 139 2004
- Lee , J.K. Two-phase flow behavior inside a header connected to multiple parallel channels Experimental Thermal and Fluid Science 33 195 202 2009
- Byun , H.W. and Kim , N.H. Refrigerant distribution in a parallel flow heat exchanger having vertical headers and heated horizontal tubes Experimental Thermal and Fluid Science 35 920 930 2011
- Zou , Y. and Hrnjak , P. Measurement and Visualization of R134a Distribution in the Vertical Header of the Microchannel Heat Exchanger SAE Technical Paper 2013-01-1498 2013 10.4271/2013-01-1498
- Zou , Y. and Hrnjak , P.S. Experiment and visualization on R134a upward flow in the vertical header of microchannel heat exchanger and its effect on distribution International Journal of Heat and Mass Transfer 62 124 134 2013
- Zou , Y. and Hrnjak , P.S. Refrigerant distribution in the vertical header of the microchannel heat exchanger - measurement and visualization of R410A flow International Journal of Refrigeration 2013
- Worsoe-Schmidt , P. Some characteristics of flow pattern and heat transfer of Freon-12 evaporating in horizontal tubes 10th International Congress of Refrigeration Copenhagen 1960
- Manwell , S.P. and Bergles , A.E. Gas-liquid flow patterns in refrigerant-oil mixtures ASHRAE Transactions 96 456 464 1990
- Poiate Jr. , E. and Gasche , J.L. Foam Flow of Oil-Refrigerant R12 Mixture in a Small Diameter Tube J. Braz. Soc. Mech. Sci. Eng. 28 4 390 398 2006
- Wongwise , S. , Wongchange , T. , Kaewon , J. and Wang , C. A Visual Study of Two-Phase Flow Patterns of HFC-134a and Lubricant Oil Mixtures Heat Trans. Eng. 23 13 22 2002
- Castro , H. , Gasche , J.L. , and Conti , W.P. Foam Flow of Oil-Refrigerant R134A Mixture in a Small Diameter Tube International Refrigeration and Air Conditioning Conference Purdue 2004
- Bowers , C.D. and Hrnjak , P.S. Effects of Oil and Saturation Temperature on Developing Two-Phase Flow of R134a in an Air-Conditioning System ASHRAE Transaction 116 290 299 2010
- Kim , S. and Hrnjak , P.S. Effect of Oil on Flow Boiling Heat Transfer and Flow Patterns of CO2 in 11.2 mm Horizontal Smooth and Enhanced Tube International Refrigeration and Air Conditioning Conference Purdue
- Tuo , H. , Bielskus , A. , and Hrnjak , P. Experimentally Validated Model of Refrigerant Distribution in a Parallel Microchannel Evaporator SAE Int. J. Mater. Manf. 5 2 365 374 2012 10.4271/2012-01-0321
- Li , H. and Hrnjak , P. Effect of Lubricant on Two-phase Refrigerant Distribution in Microchannel Evaporator SAE Int. J. Mater. Manf. 6 3 567 575 2013 10.4271/2013-01-1508
- Zou , Y. , Tuo , H. and Hrnjak , P.S. Modeling refrigerant maldistribution in microchannel heat exchangers with vertical headers based on experimentally developed distribution results Applied Thermal Engineering 64 172 181 2014