Influencing Factors on Calibration of Solid Particle Number Counting System for European PN Emission Regulations
Technical Paper
2011-01-2054
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
The European Union has announced the next term emission regulations for light-duty vehicles which include particle number (PN) emission standards. The protocol for PN counting for the regulation is described in UNECE Regulation No.83. The PN counting system required for this regulation should consist of a Volatile Particle Remover (VPR) and a Condensation Particle Counter (CPC). The regulation also requires calibration of the VPR's Particle Concentration Reduction Factor (PCRF) periodically. Since the PCRF is directly used in the calculation of PN emission, an improper calibration of the factor can cause a significant error of PN emission result. This paper investigates propriety to use NaCl particles generated by atomizing method in the PCRF calibration as reference particles. As a result, it is shown that the NaCl particles can be used in PCRF calibration because of the sufficient stability when appropriate thermal treatment is applied.
Authors
Citation
Kusaka, T., Inoue, K., and Asano, I., "Influencing Factors on Calibration of Solid Particle Number Counting System for European PN Emission Regulations," SAE Technical Paper 2011-01-2054, 2011, https://doi.org/10.4271/2011-01-2054.Also In
References
- UNECE Regulation No.83, Revision 3, Amendment 2, (E/ECE/324, E/ECE/TRANS/505 Rev.1/Add.82/Rev.3/Amend.2) 16 April 2009
- COMMISSION REGULATION (EC) No 692/2008 (OJ L199 28 7 2008
- REGULATION (EC) No 595/2009 of the European Parliament and of the Council (OJ l188 18 7 2009
- Proposal for Supplement 4 to the 05 Series of Amendments to Regulation No.49 (Emissions of Compression Ignition and Gas Fuelled Positive Ignition Engines for Use in Vehicles), ECE/TRANS/WP.29/2010/128 19 July 2010
- Tonegawa, Yoshio Aoki, Toshio Sasaki, Sousuke “Influence of Calibration Procedures for Particle Number Counting System” JSAE Spring Convention Proceedings, No.50-10, # 20105456 2010
- Giechaskiel, B. Carriero, M. Martini, G. Krasenbrink, A. et al. “Calibration and Validation of Various Commercial Particle Number Measurement Systems,” SAE Int. J. Fuels Lubr. 2 1 512 530 2009 10.4271/2009-01-1115
- Wei, Q. Akard, M. Asano, I. Rahman, M. “Penetration Calibration and Verification for the Solid Particle Counting System with Polydisperse and Monodisperse Particles,” SAE Int. J. Fuels Lubr. 1 1 593 602 2009 10.4271/2008-01-1178
- Yamada, H. Goto, Y. “Optimization of PM Measurements with a Number Counting Method,” SAE Int. J. Engines 1 1 1179 1185 2009 10.4271/2008-01-2436
- Montajir, Rahman M. Kusaka, Takeshi Kaori, Inoue Kihara, Nobutaka Asano, Ichiro Adachi, Masayuki Wei, Qiang “Soot Emission Behavior from Diverse Vehicles and Catalytic Technologies Measured by a Solid Particle Counting System” SAE Paper Number: 2007-01-0317
- Wei, Qiang Oestergaard, Karl Porter, Scott Ichiro, Asano Adachi, Masayuki Montajir, Rahman M. “Real-Time Measuring System for Engine Exhaust Solid Particle Number Emission - Design and Performance” SAE Paper Number: 2006-01-0864