High Cycle Fatigue of Cast Aluminum Alloys at Ultrasonic Frequency

2006-01-0540

04/03/2006

Event
SAE 2006 World Congress & Exhibition
Authors Abstract
Content
Ultrasonic fatigue testing machines working at approximately 20 kHz allow extending the number of testing cycles to the 108-1010 range, which would be prohibitive using conventional servo-hydraulic machines (up to 100 Hz). One of the questions that arise, however, is if the results from these very high frequency tests are comparable to the ones obtained from conventional tests performed at lower frequencies. This paper compares the high cycle fatigue (HCF) behavior of four cast aluminum alloys under two test frequencies (75 Hz and 20 kHz). It is shown that the S-N curve for some alloys is very sensitive to the testing frequency.
Meta TagsDetails
DOI
https://doi.org/10.4271/2006-01-0540
Pages
9
Citation
Engler-Pinto, C., Frisch, R., Lasecki, J., Allison, J. et al., "High Cycle Fatigue of Cast Aluminum Alloys at Ultrasonic Frequency," SAE Technical Paper 2006-01-0540, 2006, https://doi.org/10.4271/2006-01-0540.
Additional Details
Publisher
Published
Apr 3, 2006
Product Code
2006-01-0540
Content Type
Technical Paper
Language
English