This content is not included in
your SAE MOBILUS subscription, or you are not logged in.
Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation
Technical Paper
2003-01-2386
ISSN: 0148-7191, e-ISSN: 2688-3627
Annotation ability available
Sector:
Language:
English
Abstract
This paper presents a theory that explains the low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Temperature oscillations with amplitudes on the order of tens of Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There is presently no satisfactory explanation for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator power, condenser sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady state. Under certain conditions, however, the CC temperature never reaches a true steady state, but instead displays an oscillatory behavior. The proposed theory explains why low frequency, high amplitude temperature oscillations may occur when the LHP has a large thermal mass attached to the evaporator, a low applied heat load, and a very cold sink. When this condition prevails, there are some complex interactions among the CC, condenser, thermal mass and ambient, which allows the thermal mass to modulate the constant applied heat load into an oscillatory heat input to the evaporator. The oscillatory evaporator power is the source of the temperature oscillation, which can be correlated to the vapor front movement in the condenser. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.
Authors
Topic
Citation
Ku, J. and Rodriguez, J., "Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation," SAE Technical Paper 2003-01-2386, 2003, https://doi.org/10.4271/2003-01-2386.Also In
References
- Ku J. “Operating Characteristics of Loop Heat Pipes,” SAE Paper No. 1999-01-2007
- Ku J. Ottenstein L. Kobel M. Rogers P. Kaya T. “Temperature Oscillations in Loop Heat Pipe Operation,” STAIF 2001 American Institute of Physics, Albuquerque, New Mexico February 11-14, 2001
- Muto M. Nagai H. Marakami M. Ueno S. Matsuoka M. “Thermal Behavior of a Double-Condenser Design LHP for Monitor of All-Sky X-Ray Image,” SAE Paper No., 2002-01-2505 2002
- Rodriguez J. I. Na-Nakornpanom A. “Investigation of Transient Temperature Oscillations of a Propylene Loop Heat Pipe,” SAE Paper No. 2001-01-2235
- Sasin V.Y. Zelenov I. A. Zuev V.G. Kotlyarov E.Y. “Mathematical Model of a Capillary Loop Heat Pipe with a Condenser-Radiator,” SAE Paper No. 901276 1990
- Goncharov K. A. et al. “Investigation of Temperature Fluctuations in Loop Heat Pipes,” SAE Paper No. 941577 1994
- Ku J. Hoang T. “An Experimental Study of Pressure Oscillation and Hydrodynamic Stability in a Capillary Pumped Loop,” Proceedings of 31st National Heat Transfer Conference ASME HTD 307 25 32 1995
- Hoang T. Ku J. “Theory of Hydrodynamic Stability for Capillary Pumped Loops,” Proceedings of 1995 National Heat Transfer Conference ASME HTD 307 33 40 1995
- Debles S. Ochterbeck J. “Effects of Condenser Two-Phase Flow Characteristics on a Capillary Pumped Loop,” ICES Paper No. 2000-01-2321 2000
- Ku J. “High Frequency Low Amplitude Temperature Oscillations in Loop Heat Pipe Operation,” SAE Paper 2003-01-2387 2003