Detection of Shield Inhomogeneities of Muiticonductor Cables under Consideration of the Conductive Environment

1999-01-2328

06/22/1999

Event
International Conference on Lightning and Static Electricity
Authors Abstract
Content
The determination of the complex transfer impedances and transfer admittances of shielded muiticonductor cables is the prerequisite for calculating disturbing currents on the inner wires of the cable. With a measurement procedure based on the improved triaxial measurement setups using muiticonductor transmission line theory for evaluation, it is possible to determine individual transfer impedances and admittances for each inner conductor of a shielded muiticonductor cable over a broad frequency range [3]. This paper shows the determination of the location and the calculation of the area of shield inhomogeneities by the evaluation of measured transfer impedances and admittances.
Meta TagsDetails
DOI
https://doi.org/10.4271/1999-01-2328
Pages
6
Citation
Jung, L., and Haseborg, J., "Detection of Shield Inhomogeneities of Muiticonductor Cables under Consideration of the Conductive Environment," SAE Technical Paper 1999-01-2328, 1999, https://doi.org/10.4271/1999-01-2328.
Additional Details
Publisher
Published
Jun 22, 1999
Product Code
1999-01-2328
Content Type
Technical Paper
Language
English